Profile system
Specifications
Every Standard Joinery unit is fully assembled aluminium joinery from the OMEGA® 300 Series Residential Suite, manufactured in New Zealand and designed for timber-framed housing and apartments up to three storeys.
OMEGA® 300 Series profile details ↗Sizes
Fixed standard sizes as listed (height × width, mm)
Glass
Standard double-glazed insulated glass units (IGUs)
Hardware
Standard hardware — handles, stays and locks to suit unit type
Colours
Matt Black, Appliance White, Matt Titania, Matt Flaxpod
Standards
NZS 4211:2008 · NZS 4223 Parts 1–4 · NZS 3602:2003 · AS 3715:2002
Made in
New Zealand
NZ Building Code compliance
Summary from the OMEGA® 300 Series Building Product Information (November 2023).
- B1 Structure
- Tested to NZS 4211:2008 and fabricated to the structural requirements of the specified Wind Zone. Glazed to NZS 4223.3:2016 where human impact may occur.
- B2 Durability
- Finished to provide at least 15 years' durability in all Exposure Zones (excluding industrial/geothermal microclimates) when installed and maintained per OMEGA® guidelines. IGUs comply with NZS 4223.2:2016.
- C4 / D1 Escape & access
- Doors can be used within escape and access routes where specified in project requirements.
- E2 External moisture
- Tested to NZS 4211:2008 for water penetration. Suitable for installation per E2/AS1 Third Edition, with sill support bars or blocks to suit the cladding.
- E3 Internal moisture
- Glazed with IGUs; no condensation collection channels required under E3/AS1 Paragraph 1.3.
- F2 Hazardous materials
- Safe when handled per installation instructions; glazed to NZS 4223.3:2016 where specified.
- F4 Safety from falling
- Can be fitted with opening restrictors to comply with F4/AS1 Paragraph 2.0 where required.
- G4 Ventilation
- Opening sashes help provide natural ventilation per G4/AS1 Paragraph 1.2.
- G7 Natural light
- Glazing area and VLT support natural light per G7/AS1 or G7/AS2.
- H1 Energy efficiency
- Double-glazed IGUs; R-values between R0.28 and R0.56 depending on unit type, size and IGU, per H1/AS1 or H1/VM1.